Technical Bulletin 01/2019
Message
Instructions for Installation, operation and maintenance of FAS Simco perforation detectors
Date
2019-06-13
Valid for
All FAS machines with Simco perforations detector, part no. 205528
Background
FAS introduced new perforation detectors in 2014, a joint development with Simco where the electrode heads (1Mohm) are designed for FAS. The detectors have performed very well, incorrect handling and settings has been the root cause for most the few complaints we have received.
General
The Simco perforation detectors works with high accuracy and with good life time if they are set and maintained according the suppliers instructions. With lower power setting the life time can be expected to be longer.
Contact
If you have any questions or concerns please contact us via “service@fasconverting.com”
Installation
1. The plastic screws shall be tightened by means of fingers only, no tools shall be used
2. Check that the plastic washer between the housing and the bracket is in place, this is valid even if the holder is made of plastic (lower picture)
3. The unit shall be set parallel and at 2-4 mm distance from the neutral shaft
The unit shall not touch the film.
Operation
With lower power setting the life time is increased. Reduce the power setting until the led stops flashing, then increase the power by using the potentiometer until you have a stable detection.
The Operator panel might be looking different depending on machine type.
Make sure the electrodes are clean
Make sure the neutral shaft is clean
Make sure the film is not touching the detector
Sparks are often not visible with this unit, the green led on the unit is flashing red when a perforation is detected.
Maintenance
• Disconnect the power supply before carrying out work on the unit.
• The electrode head is the only component of the unit that requires maintenance. If needed, clean it by use of a soft non-metal brush
– If very dirty, clean with isopropyl alcohol or with Veconova 10 industrial cleaner
– Make sure the unit is completely dry before operating it againolor sit amet, consectetur adipiscing elit. Vivamus sagittis nisi eu justo ullamcorper laoreet. Suspendisse vestibulum bibendum nulla, eget tempus orci dictum sed. Vestibulum turpis nulla, ornare a porttitor in, tincidunt id ante. Etiam pellentesque ex vel interdum mollis.
Spare parts numbers
•Electrode head 205754
•Electrode 205753 (3pcs)
•Complete Detector 205528
•Soft non metal brush 206249
We also have Simco perforation detector upgrade kits for most of our older machine types, please contact us via service@fasconverting.com for more information